Seitenansicht 23
Installation Guide
69-2307—01 22
sPeCIfICaTIons
Capacity:
RXIH-AS12A: 12 gallons per day (gpd)
(45litersperday[lpd])
RXIH-AS09A: 9 gpd (34 lpd)
RXIH-AS06A: 6 gpd (23 lpd)
Humidified Area:
House
Description
Air Changes
Per Hour
RXIH-
AS12A
RXIH-
AS09A
RXIH-
AS06A
Loose Two 2000 ft
2
1300 ft
2
1000 ft
2
Average One 2500 ft
2
1800 ft
2
1500 ft
2
Tight One-half 3000+ ft
2
2500 ft
2
2000 ft
2
Weight:
Model Empty Filled with Water
RXIH-AS12A 9 lbs. 15 lbs.
RXIH-AS09A 9 lbs. 14.5 lbs.
RXIH-AS06A 8 lbs. 12 lbs.
• Dimensions:11-1/4in.Wx19in.Hx9in.D
• HumidifierOperatingTemperatureRange:34ºF–
120ºF (1.1ºC–49ºC)
• RemoteHose/NozzleOperatingTemperatureRange:
-50ºF–250ºF (-46ºC–121ºC)
• OperatingHumidityRange:0–95%RH,non-
condensing
Drain Operation
• Autoflushingisconfigurableto10,20or30hoursof
operational time (heating element active).
• Duringautoflushing,coldwaterwillenterthetankto
lower water temperature below 140ºF (60ºC) before
draining.
• Duringmanualflush(performedbypressingthe
EMPTYbutton)initialwatertemperaturemaybe
above140ºF(60ºC).Ensuredrainoutletisnot
exposedandusecautionwhenpressingtheEMPTY
button, and do NOT attempt to remove the tank with
water in it.
• Flushcycletakesapproximately15minutesto
empty the tank completely. To override, press/hold
theEMPTYbuttonwhilethe“CleanTank”lightis
blinking.
• DrainHoseOperatingTemperatureRange:
34ºF–212ºF (1.1ºC–100ºC)
Electrical Ratings and Tolerances
Input Ratings
• PowerSupply:120VAC+10/-15%,60Hz
- RXIH-AS12A: 1440W at 120VAC at full load
- RXIH-AS09A: 1200W at 120VAC at full load
- RXIH-AS06A: 840W at 120VAC at full load
• RXIH-AS12A:12A,120VAC
• RXIH-AS09A:10A,120VAC
• RXIH-AS06A:7A,120VAC
• 15A,120VACinterlockswitch
• Thermostat/HVACpowermonitor(RtoC):10mA
resistive at 24VAC
• Fieldwiringterminals:18–22ga.solid
• HVACpower/airflowmonitor:10mAresistiveat24
VAC
Output Ratings
• Relayoutputcontacts:
- Fan: 1.5A full load, 7.5A locked rotor at 24VAC
- Heat and Backup: 15A resistive at 120VAC
• FillSolenoid:0.1Aat120VAC,0.5PF
• DrainSolenoid:0.1Aat120VAC,0.5PF
• Humidistatoutputcontacts:10mAresistiveat24VAC
• Humidistatpowersupply:100mAat24VAC
Standards & Approval Body Requirements
UnderwritersLaboratories:UL998,Fileno.E185662.
FederalCommunicationsCommission:ClassBcompliance,Fileno.YU555.
IntendedtobeusedinaccordancewiththeNationalElectricalCode(NEC),ANSI/NFPA70,andtherulesofthe
CanadianElectricalCode(CEC),Part1,C22.1.
CAUTION
Hot water temperature above 140°F (60°C)
can cause burns from scalding.