Rheem GEN12AD-V Bedienungsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 6
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
7HOME STANDBY GENERATOR SYSTEMS
TRANSFER SWITCHES
How It Works
Automatically manages the transition between the electric utility service
and generator as follows:
Continuously monitors the connection to local utility power
When utility power is disrupted, the transfer switch confirms that a true
power outage has occurred and signals the standby generator to start
The system supplies backup power to the home within 30 seconds.
Air Condition Control Module (ACCM)
As noted, some switches contain an ACCM (Air Condition Control Module),
a patented Power Management technology that supervises the power
demands of up to two central air-conditioners while safeguarding against
power overload
Service Disconnect Option
As noted, some Transfer Switches are suitable for use as the Service
Entrance Disconnect; these switches may be optionally connected directly
after the home’s utility watt-hour meter, instead of being connected
downstream of the main panelboard
Current Capacity Rating Options
Automatic transfer switches come in four sizes: 50A, 100A, 200A and 400A;
if the Transfer Switch will also serve as the Service Disconnect, it will need to
have a current capacity rating at least as great as the main breaker on the
main panelboard. (Note: 200A main breakers are common in many new
homes, while older homes often have 100A)
Panelboard Option
As noted, some switches include a panelboard within the transfer switch
enclosure; in cases where the Transfer Switch will not be used as the Service
Disconnect, you may want to consider the option of choosing Transfer
Switch that includes a panelboard, since this will eliminate the need to
purchase a separate subpanel
Outdoor Enclosure
All transfer switches include a rainproof NEMA 3R outdoor enclosure
SERVICE ENTRANCE CURRENT DIMENSIONS
PART NO DISCONNECT RATING CAPACITY (A) PANELBOARD ACCM L X W X H (IN) WEIGHT (LBS)
TS509C No 50 9 Positon Not Available 14-1/4 x 6 x 21 30
Transfer Switch – SEREGEN 50 Series
SERVICE ENTRANCE CURRENT DIMENSIONS
PART NO DISCONNECT RATING CAPACITY (A) PANELBOARD ACCM L X W X H (IN) WEIGHT (LBS)
TS100A No 100 Not Included Included 14 x 6 x 22 32
TS100A16 No 100 16 Position Included 27 x 9-1/2 x 17 37
TS100AD Yes 100 Not Included Included 14 x 6 x 22 32
TS200A No 200 Not Included Included 16 x 7 x 30 53
TS200AD Yes 200 Not Included Included 16 x 7 x 30 53
Transfer Switch – SEREGEN 100 & 300 Series
SERVICE ENTRANCE CURRENT DIMENSIONS
PART NO DISCONNECT RATING CAPACITY (A) PANELBOARD ACCM L X W X H (IN) WEIGHT (LBS)
TS200ADW Yes 200 Not Included Included 38 x 14 x 24 64
TS400 No 400 Not Included Not Available 46 x 24 x 15 190
Transfer Switch – SEREGEN 400 Series