Rheem 2-stage Spezifikationsblatt

Stöbern Sie online oder laden Sie Spezifikationsblatt nach Nein Rheem 2-stage herunter. Rheem 2-Stage Specification Sheet [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 12
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
FORM NO. A11-189 REV. 2
Supersedes Form No. A11-189 Rev. 1
CONDENSING UNITS
18.0
RASL- JEZ
Two-Stage
Efficiencies up to 18.50 SEER
Nominal Size 2 to 3 Tons [7.03 kW] to [10.6 kW]
Two Models
Cooling Capacity
24,000 to 37,600 BTU/HR
[7.03 kW] to [11.02 kW]
The Rheem Prestige Series
®
High Efficiency Two-Stage RASL-
JEZ Condensing Unit was designed with performance in mind.
These units offer comfort, energy conservation and dependability
for single, multi-family and light commercial applications.
The Rheem Prestige Series
®
Two-Stage RASL- JEZ Condensing
Units are the result of an ongoing development program for
improved efficiencies. With system SEER’s ranging to 18.50,
these units continue a tradition of high efficiency.
■ The Comfort Control System
™
provides on-board diagnostics
and fault history for condensing units with single-phase com-
pressors by detecting system and electrical problems without
adding sensors. It can also communicate “fault codes” to
enabled “L terminal” thermostats. The integrated diagnostics
with Active Protection
™
prevents compressor operation when
potentially harmful conditions are detected.
■
7-Segment LED Display is exclusive only to Rheem products.
The information-display quickly and accurately shows techni-
cians the source of malfunctions.
■
Ten-year conditional unit replacement warranty.
■ Reliable Two-Stage Scroll™ Compressor for precise tempera-
ture control providing ultimate comfort.
■ Comfort Alert™ Diagnostics comes installed in each Rheem
Prestige Series model.
■ All controls are accessible by removing one service panel.
Removable top grille provides access to the condenser fan
motor and condenser coil.
■ Attractive, louvered wrap-around jacket protects the coil from
yard hazards and weather extremes. Top grille is steel rein-
forced for extra strength. Cabinet is powder painted for all-
weather protection.
■ Air is discharged upward away from bushes and shrubs. The
discharge pattern of the top grille provides minimum air restric-
tion, resulting in quiet fan operation.
■ Exclusive Combination Grille/Motor Mount secures the motor to
the underside of the discharge grille. The grille protects the
motor windings and bearings from rain and snow.
■ For quiet operation and improved efficiency, the 3 ton model fea-
ture the GE
®
ECM two-speed motor with a 3-blade outdoor fan.
■ All models meet or exceed a 1000-hour salt spray test per ASTM
B117 Standard Practice for Operating Salt Spray Testing
Apparatus.
■ On-demand dehumidification terminal, when matched with a
Prestige Series Air Handler or premium ECM Gas Furnace prod-
ucts, adjusts airflow to help control humidity for unsurpassed
comfort in the cooling mode.
earth friendly refrigerant
Equipped with
the Award Winning
Comfort Control System
™
• Increased Reliability
• On-Board Diagnostics
• Fault Recall
• Active Protection
™
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - CONDENSING UNITS

FORM NO. A11-189 REV. 2Supersedes Form No. A11-189 Rev. 1CONDENSING UNITS18.0RASL- JEZTwo-StageEfficiencies up to 18.50 SEER Nominal Size 2 to 3 Tons

Seite 2 - COMPRESSOR

Rheem will furnish a replacement for any part of this productwhich fails in normal use and service within the applicableperiod stated, in accordance w

Seite 3 - Accessories

Rheem Manufacturing Company 11Condensing Unit Refrigerant Line Size InformationSuction Line Connection Size25' [7.62]50'[15.24]100' [30

Seite 4 - Model Number Identification

“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”PRINTED IN U.S.A.

Seite 5 - Rheem Manufacturing Company 5

2 Rheem Manufacturing Company The Rheem exclusive 7-Segment LED Display easily showssystem operating status codes anddiagnostic codes. A Sealed Switch

Seite 6 - 6 Rheem Manufacturing Company

Rheem Manufacturing Company 3 Accessories Low Ambient Control—Cycles outdoor fan to maintainadequate condensing pressures assuring liquid refrigeran

Seite 7 - Rheem Manufacturing Company 7

4 Rheem Manufacturing CompanyR A S L 036COOLINGCAPACITY024 = 24,000 BTU/HR [7.03 kW]036 = 36,000 BTU/HR [10.55 kW]J E ZRHEEM REMOTECONDENSINGUNIT

Seite 8 - 8 Rheem Manufacturing Company

Rheem Manufacturing Company 5NetSensibleBTU/H [kW]OutdoorUnitRASL-ARI Cooling Performance80°F [26.5°C] DB / 67°F [19.5°C] WB Indoor Air95°F [35°C] DB

Seite 9 - Rheem Manufacturing Company 9

6 Rheem Manufacturing CompanyNetSensibleBTU/H [kW]OutdoorUnitRASL-ARI Cooling Performance80°F [26.5°C] DB / 67°F [19.5°C] WB Indoor Air95°F [35°C] DB

Seite 10 - Unit Dimensions

Rheem Manufacturing Company 7NetSensibleBTU/H [kW]OutdoorUnitRASL-ARI Cooling Performance80°F [26.5°C] DB / 67°F [19.5°C] WB Indoor Air95°F [35°C] DB

Seite 11

8 Rheem Manufacturing CompanyNetSensibleBTU/H [kW]OutdoorUnitRASL-ARI Cooling Performance80°F [26.5°C] DB / 67°F [19.5°C] WB Indoor Air95°F [35°C] DB

Seite 12 - DIVISION

Rheem Manufacturing Company 9NetSensibleBTU/H [kW]OutdoorUnitRASL-ARI Cooling Performance80°F [26.5°C] DB / 67°F [19.5°C] WB Indoor Air95°F [35°C] DB

Kommentare zu diesen Handbüchern