Rheem (RA13) Spezifikationsblatt Seite 1

Stöbern Sie online oder laden Sie Spezifikationsblatt nach Nein Rheem (RA13) herunter. Rheem (RA13) Specification Sheet Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
15.5
Rheem Classic
®
Series
Air Conditioners
FORM NO. A11-221 REV. 1
New composite base pan – dampens sound, captures louver
panels, eliminates corrosion and reduces number of fasteners
needed
Powder coat paint system – for a long lasting professional finish
Scroll compressor – uses 70% fewer moving parts for higher
efficiency and increased reliability
Modern cabinet aesthetics – increased curb appeal with visu-
ally appealing design
Curved louver panels – provide ultimate coil protection,
enhance cabinet strength, and increased cabinet rigidity
Optimized fan orifice – optimizes airflow and reduces unit
sound
Rust resistant screws – confirmed through 1500-hour salt
spray testing
PlusOne™ Expanded Valve Space – 3"-4"-5" service valve
space – provides a minimum working area of 27-square
inches for easier access
PlusOne™ Triple Service Access – 15" wide, industry lead-
ing corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to
internal unit components. Individual louver panels come out
once fastener is removed, for faster coil cleaning and easier
cabinet reassembly
Diagnostic service window with two-fastener opening –
provides access to the high and low pressure.
External gauge port access – allows easy connection of
“low-loss” gauge ports
Single-row condenser coil – makes unit lighter and allows
thorough coil cleaning to maintain “out of the box”
performance
35% fewer cabinet fasteners and fastener-free base – allow
for faster access to internal components and hassle-free
panel removal
Service trays – hold fasteners or caps during service calls
QR code – provides technical information on demand for
faster service calls
Fan motor harness with extra long wires allows unit top to be
removed without disconnecting fan wire.
Air
Air Conditioners
RA13 Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Dealer for details or visit
www.energystar.gov.”
RA13 Series
Efficiencies 13-15.5 SEER/11.5-13 EER
Nominal Sizes 1
1
/2 to 5 Ton [5.28 to 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Air Conditioners

15.5Rheem Classic®SeriesAir ConditionersFORM NO. A11-221 REV. 1• New composite base pan – dampens sound, captures louverpanels, eliminates corrosion a

Seite 2 - TABLE OF CONTENTS

Unit DimensionsMODELNO.OPERATING SHIPPINGH (Height) L (Length) W (Width) H (Height) L (Length) W (Width)INCHES mm INCHES mm INCHES mm INCHES mm INCHES

Seite 3 - Available SKUs

6⬙ (152.4)24⬙ (609.6)Service12⬙ (304.8)6⬙ (152.4)24⬙ (609.6)Service24⬙ (609.6)24⬙ recommended9⬙ minimum12⬙ (304.8)12⬙ (304.8)6⬙ (152.4)24⬙ (609.6)Serv

Seite 4 - Features & Benefits

FIGURE 2CONTROL WIRING FOR GAS OR OIL FURNACEFOR TYPICAL ELECTRIC HEATFOR TYPICAL GAS OR OIL HEATCYGWRW/BLRW/BKG/BKYLBRPUYGWRTYPICAL THERMOSTATSUBBASE

Seite 5 - Optional Accessories

AirRefrigerant Line Size InformationRA13 Series13R-410A SystemCapacity ModelLiquid Line SizeConnection Size(Inch I.D.) [mm]Liquid Line Size(Inch O.D.)

Seite 6

AirRefrigerant Line Size InformationRA13 Series14R-410A SystemCapacity ModelVapor LineConnection Size(Inch I.D.) [mm]Vapor Line Size(Inch O.D.) [mm]Va

Seite 7 - (For Reference)

AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – CoolingHigh Sales Volume Tested Combination (HSVTC)OutdoorUnitIndoor CoilT

Seite 8 - Electrical Data

AirPerformance DataRA13 Series16Performance Data @ AHRI Standard Conditions – Cooling (con’t.)R801T Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 9 - Thermostats

AirPerformance DataRA13 Series17Performance Data @ AHRI Standard Conditions – Cooling (con’t.)R801T Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 10 - Unit Dimensions

18AirPerformance DataRA13 Series18Performance Data @ AHRI Standard Conditions – Cooling (con’t.)R801T Furnace RatingsOutdoorUnitFurnace Indoor CoilTot

Seite 11 - CLEARANCES

19AirPerformance DataRA13 Series19Performance Data @ AHRI Standard Conditions – Cooling (con’t.)R801T Furnace RatingsOutdoorUnitFurnace Indoor CoilTot

Seite 12 - Control Wiring

AirTable of ContentsRA13 Series2TABLE OF CONTENTSStandard Feature ...

Seite 13

AirPerformance DataRA13 Series20Performance Data @ AHRI Standard Conditions – Cooling (con’t.)R95T Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 14

21AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)R95T Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 15 - RA13 Series

22AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGFG Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 16

23AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGFG Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 17

24AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGFG Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 18

25AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGJF Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 19

26AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGJF Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 20

27AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGJF Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 21

28AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPE Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 22

29AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPE Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 23

AirStandard Feature/Available SKUsRA13 Series3STANDARD FEATURESFeature 18 24 30 36 42 48 60R-410a Refrigerant √ √ √ √ √ √ √Maximum SEER 15.1 15.0 15.5

Seite 24

30AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPE Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 25

31AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPT Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 26

32AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGPT Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 27

33AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)RGRM Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 28

34AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)ROCA Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 29

35AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)ROCA Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 30

36AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)ROLA Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 31

37AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)ROLA Furnace RatingsOutdoorUnitFurnace Indoor CoilTotal

Seite 32

38AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)Air Handler RatingsOutdoorUnitAir HandlerTotal CapacityB

Seite 33

39AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)Air Handler RatingsOutdoorUnitAir HandlerTotal CapacityB

Seite 34

The RA13 is our 13 SEER air conditioner and is part of theRheem air conditioner product line that extends from 13 to 20SEER. This highly featured and

Seite 35

40AirPerformance DataRA13 SeriesPerformance Data @ AHRI Standard Conditions – Cooling (con’t.)Air Handler RatingsOutdoorUnitAir HandlerTotal CapacityB

Seite 36

AirGuide SpecificationsRA13 Series41GUIDE SPECIFICATIONS GeneralSystem DescriptionOutdoor-mounted, air-cooled, split-system air conditioner com-posite

Seite 37

AirLimited WarrantyRA13 Series42GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal u

Seite 38

AirNotesRA13 Series43

Seite 39

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Seite 40

AirFeatures & BenefitsRA13 Series5The entire cabinet has powder post paint ( ) achieving 1000hour salt spray rating, allowing the cabinet to retai

Seite 41 - Products

RA 13 24 AJ1 N A *Brand ProductCategorySEER CapacityBTU/HRMajor Series* Voltage Type Controls Minor Series** Option CodeRheem A - Air Conditioners 13

Seite 42

R96 V A702 3 17 M S ABrand Series Motor Major Rev InputBTU/HRStages Air Flow CabinetWidthConfiguration Nox Minor RevRheem 90 - 90 AFUE92 - 92 AFUE95 -

Seite 43

AirGeneral Data/Electrical DataRA13 Series8Physical DataPHYSICAL DATAModel No. RA1318A RA1324A RA1330A RA1336A RA1342A RA1348A RA1360ANominal Tonnage

Seite 44 - The new degree of comfort

AirAccessories/Weighted Sound Power/ThermostatsRA13 Series9AccessoriesModel No. RA1318 RA1324 RA1330 RA1336 RA1342 RA1348 RA1360Compressor crankcase h

Kommentare zu diesen Handbüchern

Keine Kommentare