INTELLI-VENT TROUBLESHOOTING GUIDE
Technical Training Department Ashland City, Tennessee © 2005
2 of 24
INTELLI-VENT™ CONSTRUCTION
Manifold Gas;
Main Burner Connection
RH thread Natural
LH thread Propane
Bottom View
Right Side View
Manifold Gas
Pressure Tap
Control
Information
6 Pin Molex Plug
Line Voltage
Blower Voltage
Pressure Switch
5 Pin Molex Plug
Hot Surface Ignitor
Flame Sensor
Resistor Wire
Ignitor Assembly
Flame Sensor
Silicon Nitride Ignitor
(Hot Surface Ignitor)
Front & Left Side View
Temperature Probe/ECO
6 LED indicator lights
Temperature Settings
Error Codes / Diagnostics
Supply Gas Connection
Future side connect model is
shown here. Top connect models
are in use currently.
Temperature adjust buttons
Temperature adjust buttons
must be pressed together for
one second to “wake up” the
control in order to view or
change temperature settings.