General Construction
Part B Specification and Response Requirements
Annexure 2- Minimum Design & Construction Specification
Page 54 Updated 19/07/2013
The sheet materials shall be laid horizontally, with staggered joins, if room length sheets are
not possible, and fixed into the studs as per the manufacturer’s recommendations for use as
a wall lining. .
3.7 INSULATION
Insulation shall be in sheets or batts and of a type that conforms to AS Codes and current
BCA requirements and is fire resistant (non-flammable).
The following minimum shall apply:
(i) Provide minimum R3.0 thermal resistance bulk insulation to all ceilings to Living
Areas only. Ceiling insulation to Garages & Carports is NOT required unless
needed to meet the energy efficiency requirements of the BCA.
(ii) Provide R1.5 thermal resistance bulk insulation to external walls enclosing the
Living Area. Where a timber or steel framed partition type wall divides the living
space from a fully enclosed garage, that wall is required to be insulated. Internal
partition walls within the living area are NOT required to be insulated unless
needed to meet the energy efficiency requirements of the BCA.
(iii) Extend insulation to the top of the ceiling insulation at the external walls.
3.8. WINDOWS
3.8.1 General
Frames shall be shop fabricated into complete assemblies as detailed and scheduled
Protect aluminium and pre-treat timber work before it leaves the workshop.
Accurately position and build into the work.
All windows shall be completed with flashings and hardware, shop fitted where practicable.
All glass and glazing shall comply with AS 1288
3.8.2 Aluminium windows
3.8.2.1 General
The aluminium extrusions shall comply with AS1866 and be at least equivalent to Australian
Alloy B6063, temper designation T5. Unless specified otherwise, manufacture and install
frames in accordance with AS2047. Unless otherwise scoped the minimum wind rating shall
be N2 and the frame shall be marked accordingly.
Joints shall be accurately machined and screws shall be 18/8 type stainless steel. Reinforce
mitres with extruded or pressed metal splines and seal joints with polyurethane on assembly.
3.8.2.2 Finish
All aluminium shall be powder coated to AS3715 colour as scheduled with powder coating
complying with APAS 0155/2 to a minimum thickness of 40µm, or anodized to AS1231 with a
minimum coating thickness of 15µm, with all exposed surfaces free from blemishes.