CONNECTIONS PLUMBING
CONNECTION SIZES
Model
871 018
875 018
871 020
-
871 022
875 022
871 024
875 024
871 026
875 026
Hot water connection
R½/15
R¾/20
R¾/20
R¾/20
R¾/20
Cold water connection
R½/15
R¾/20
R¾/20
R¾/20
R¾/20
Gas inlet connection
R¾/20
R¾/20
R¾/20
R¾/20
R¾/20
All plumbing work must be carried out by a qualified person and in accordance with the National Plumbing
Standard AS/NZS 3500.4 and local authority requirements.
All gas work must be carried out by a qualified person and in accordance with the Australian Gas
Installations Standard AS 5601 and local authority requirements.
WATER INLET AND OUTLET
All pipe work must be cleared of foreign matter before connection
and purged before attempting to operate the water heater. All
olive compression fittings must use brass or copper olives. Use
thread sealing tape or approved thread sealant on all fittings.
A full flow gate valve or ball valve must be installed on the cold
water line or solar preheat water line to the water heater. A non
return valve or stop tap must not be installed. An acceptable
arrangement is shown in the diagram. Refer also to “Hot Water
Delivery” on page 45 and to “Mains Water Supply” on page 44.
A disconnection union must always be provided at the cold water
inlet and hot water outlet on the water heater to allow for
disconnection of the water heater.
Insulation used on the cold and hot water lines must extend up to
the cold water inlet and hot water outlet of the water heater.
Notes:
It is essential all pipe connections be correctly aligned,
otherwise component connections within the water heater
may be strained and / or components themselves
misaligned. It is recommended also, wherever possible, pipe
connections be made at the water heater first and final pipe
runs be made in soft copper pipe to allow some adjustment
for misalignment.
Use the spanner flats on the water heater fittings and take
care to avoid twisting the water inlet and outlet pipes inside
the jacket.
871 series gas booster water heaters with the following or a
later suffix letter after the model number on the rating label of
the water heater do not need to be installed with a solar
bypass valve:
018 and 020 models - B
022 models - A
024 models - C
026 models - B
The maximum supply temperature to the water heater when used as an in-series gas booster for a solar
preheat water heater is 80°C.
Gas Water Heater
Cold and Hot Water Connection Details
Gas Booster for a Solar Preheater
Solar Preheat and Hot Water
Connection Details