COMMISSIONING
69
PRESET OUTLET TEMPERATURE
The factory preset outlet temperature of the water heater is:
871 series (pre 2007 manufacture date) 50°C
871 series (from 2007 manufacture date) 60°C
875 series 48°C
If a temperature controller is connected to the water heater, this will override the preset outlet temperature
setting and the maximum outlet temperature will be:
Maximum Outlet Temperature
Kitchen controller connected
Bathroom controller only connected
It is usually not necessary to check or adjust the factory preset outlet temperature of the water heater, unless
the customer has a particular requirement for this to be done or it is to be installed as a gas booster to a
solar water heater.
Gas Booster for a Solar Water Heater
Where an 871 series water heater is installed as a gas booster to a solar water heater, the preset outlet
temperature must be set at 60 C for the system to operate correctly.
It will be necessary to check and if required to adjust the preset outlet temperature of the continuous flow
water heater when:
it is installed as a gas booster as part of a solar water heater installation
it is an existing continuous flow water heater and a solar preheat water heater is then installed.
Notes:
Consideration must be given to the delivery temperature to any ablution and public areas such as a
bathroom, ensuite or public amenities. Refer to “Hot Water Delivery” on page 45 and to “Schematics of 2
Temperature Zones Using A Temperature Limiting Device” on page 46.
The 875 series water heater, marked “THIS APPLIANCE DELIVERS WATER NOT EXCEEDING 50°C
IN ACCORDANCE WITH AS 3498” on the front panel, must not be installed as an in-series gas booster
water heater to a solar water heater, as water temperature greater than 50°C can be delivered from the
water heater contravening its compliance to AS 3498.