This water heater must be installed and serviced by an authorised person. Please leave this guide with the householder. Owner’s Guide and Installation
10 TEMPERATURE CONTROL – STANDARD STANDARD CONTROLLER FUNCTIONS If one or more controllers are installed, at least one must be on for
TEMPERATURE CONTROL – STANDARD 11 STANDARD CONTROLLER integrity Note: water volume button, water volume operating light and water volume symbol are
TEMPERATURE CONTROL – STANDARD 12 TEMPERATURE SETTINGS – STANDARD CONTROLLER The temperature settings of each type of controller are: Bathroom1 &
TEMPERATURE CONTROL – STANDARD 13 TEMPERATURE ADJUSTMENT – STANDARD CONTROLLER A controller must be on and have priority to be able to adjust the te
TEMPERATURE CONTROL – STANDARD 14 KITCHEN CONTROLLER – STANDARD The Kitchen controller allows the user to select the temperature setting for the hot w
TEMPERATURE CONTROL – STANDARD 15 To operate the Kitchen controller: 1. Turn off the Bathroom controller(s) If a temperature setting is displayed
TEMPERATURE CONTROL – STANDARD 16 BATHROOM CONTROLLERS – STANDARD The Bathroom controller(s) allows the user to select the temperature setting for the
TEMPERATURE CONTROL – STANDARD 17 ch e ck h o t wa t e r te m p er a t u re b e fo r e u se on of f 40 C pr i o rity in u s e 42 C pr i o
TEMPERATURE CONTROL – STANDARD 18 WATER VOLUME FUNCTION – STANDARD CONTROLLER The water volume function is designed to warn, by a beeping sound, that
TEMPERATURE CONTROL – STANDARD 19 5. Turn off the alarm Press the water volume button to turn off the alarm. The water volume operating light goes
PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd or Paloma Industries L
20 TEMPERATURE CONTROL – DELUXE DELUXE CONTROLLER FUNCTIONS If one or more Deluxe controllers are installed, at least one must be on or the bath fil
TEMPERATURE CONTROL – DELUXE 21 bath fill water volume display panel – The selected bath fill water volume is displayed in litres on all Deluxe contro
TEMPERATURE CONTROL – DELUXE 22 VOICE PROMPT AND OPERATING TONE The Deluxe controllers have a series of voice prompts and operating tones
TEMPERATURE CONTROL – DELUXE 23 Adjusting the Volume of the Voice Prompt and Operating Tone The volume of the voice prompt and the operating tone can
TEMPERATURE CONTROL – DELUXE 24 TEMPERATURE SETTINGS – DELUXE CONTROLLERS The temperature settings of each type of Deluxe controller are: Bathroom1
TEMPERATURE CONTROL – DELUXE 25 TEMPERATURE ADJUSTMENT – DELUXE CONTROLLERS A controller must be on with the ACTIVE indicator displayed to be able t
TEMPERATURE CONTROL – DELUXE 26 KITCHEN CONTROLLER – DELUXE The Kitchen Deluxe controller allows the user to select the temperature setting for the ho
TEMPERATURE CONTROL – DELUXE 27 To operate the Kitchen Deluxe controller: 1. Turn off the Bathroom Deluxe controller(s) If a temperature setting
TEMPERATURE CONTROL – DELUXE 28 BATHROOM CONTROLLERS – DELUXE The Bathroom Deluxe controller(s) allows the user to select the temperature setting for
TEMPERATURE CONTROL – DELUXE 29 To operate a Bathroom Deluxe controller: 1. Turn off the Kitchen Deluxe controller If a temperature setting is di
3 CONTENTS HOUSEHOLDER - We recommend you read pages 4 to 41. The other pages are intended for the installer but may be of interest. About Your W
TEMPERATURE CONTROL – DELUXE 30 BATH FILL MODE The Bath Fill mode is designed to allow the water heater to deliver a selected volume of water at a sel
TEMPERATURE CONTROL – DELUXE 31 5. Close the front panel on the Deluxe controller. 6. Turn on the Bath Fill mode Press the BATH FILL button. On
TEMPERATURE CONTROL – DELUXE 32 Bath Fill Mode – Explanatory Notes To operate the Bath Fill mode: 1. Turn off all Deluxe controllers It is advise
TEMPERATURE CONTROL – DELUXE 33 4. Set the bath fill water volume Press the BATH FILL VOLUME (up button) or the BATH FILL VOLUME (down button)
TEMPERATURE CONTROL – DELUXE 34 7. Open the hot tap. The operating light will glow on all Deluxe controllers. Measurement of the water flow at the
TEMPERATURE CONTROL – DELUXE 35 Turning Off Bath Fill Mode During Its Operation The bath fill operation can be interrupted by pressing the BATH FILL b
TEMPERATURE CONTROL – DELUXE 36 Notes on the Bath Fill mode: The Bath Fill mode can be set and turned on at any of the Deluxe controllers. The Del
TEMPERATURE CONTROL – DELUXE 37 Opening a Second Hot Water Tap During Bath Fill Operation The bath fill water volume is measured as the water flows
TEMPERATURE CONTROL – DELUXE 38 Operation of the Bath Fill mode whilst a Deluxe Controller is ACTIVE It is recommended the Bath Fill mode be set and o
39 SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending to any condition or fault, which is not
4 ABOUT YOUR WATER HEATER MODEL TYPE The Rheem® electronic continuous flow gas water heater model you have chosen is for outdoor installation only.
SAVE A SERVICE CALL 40 GAS BOOSTER OPERATING TOO FREQUENTLY If the water heater is installed as a gas booster water heater to a solar preheat water he
SAVE A SERVICE CALL 41 CLOUDS OF WHITE ‘VAPOUR’ FROM THE FLUE TERMINAL During the heating cycle, it is not unusual to see water vapour clouds steaming
42 INSTALLATION – WATER HEATER THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the wat
INSTALLATION – WATER HEATER 43 As a guide the following requirements extracted from the Australian Gas Installations Standard AS 5601, must
INSTALLATION – WATER HEATER 44 MAINS WATER SUPPLY Where the mains water supply pressure exceeds that shown in the table below, an approv
INSTALLATION – WATER HEATER 45 HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. It is necessary and w
INSTALLATION – WATER HEATER 46 Where a temperature limiting device is installed adjacent to the gas booster water heater, the cold water line to the t
INSTALLATION – WATER HEATER 47 CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A Rheem continuous flow water heater cannot be installed as part of a circu
INSTALLATION – WATER HEATER 48 WATER TEMPERATURE DIAGRAMS 871 Series - Kitchen and Bathroom Controllers 875 Series – Kitchen and Bathroom Cont
INSTALLATION – WATER HEATER 49 DIMENSIONS AND TECHNICAL DATA Model 871 018 875 018 871 020 - 871 022 875 022 871 024 875 024 871 026 875 026 R
ABOUT YOUR WATER HEATER 5 MAINS PRESSURE The water heater is designed for direct connection to the mains water supply. If the mains supply pressure in
INSTALLATION – WATER HEATER 50 DIMENSIONS – STANDARD CONTROLLERS Kitchen Controller (Standard) Bathroom Controller (Standard)
INSTALLATION – WATER HEATER 51 DIMENSIONS – DELUXE CONTROLLERS U UPSet Bath Fill Water Volumeand TemperatureBathWaterVolumeBathFillTempBath Fill1.
INSTALLATION – WATER HEATER 52 TYPICAL INSTALLATION – OUTDOOR LOCATION 871, 875, 241, 245 SERIES CONTINUOUS FLOW GAS WATER HEATERTYPICAL INSTALLATIO
INSTALLATION – WATER HEATER 53 TYPICAL INSTALLATION – GAS BOOSTER FOR OPEN CIRCUIT SOLAR LOLINE Typical Installation - Solar In-Line Gas BoosterSolar
INSTALLATION – WATER HEATER 54 TYPICAL INSTALLATION – GAS BOOSTER FOR OPEN CIRCUIT SOLAR HILINE TYPICAL INSTALLATIONSOLAR THERMOSIPHON WITH IN-SERIES
55 CONNECTIONS – PLUMBING CONNECTION SIZES Model 871 018 875 018 871 020 - 871 022 875 022 871 024 875 024 871 026 875 026 Hot water connection R½/1
CONNECTIONS – PLUMBING 56 PIPE SIZES The pipe sizing for hot water supply systems should be carried out by persons competent to do so, choosing the m
57 CONNECTIONS – ELECTRICAL All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the Wiring Rul
58 INSTALLATION – CONTROLLERS CONTROLLERS The Rheem 871 and 875 series can be installed with Rheem controllers to enable the user to control the tem
INSTALLATION – CONTROLLERS 59 Location – The controllers must be installed in dry, shaded and clean locations. Do not install the controllers: Near
ABOUT YOUR WATER HEATER 6 WARNING This water heater is only intended to be operated by persons who have the experience or the knowledge and the capab
INSTALLATION – CONTROLLERS 60 Wiring installation: 1. Penetrate the wall with a 30-35 mm hole at the controller location. 2. Install the Kitchen con
INSTALLATION – CONTROLLERS 61 If it is necessary to have an exposed wiring installation, follow this procedure omitting Steps 1 and 4, and make an ope
INSTALLATION – CONTROLLERS 62 BATHROOM1 AND BATHROOM2 CONTROLLERS If only one Bathroom controller is to be installed, the standard Bathroom1 Controlle
INSTALLATION – CONTROLLERS 63 Wiring installation: 1. Penetrate the wall with a 30-35 mm hole at the controller location. 2. Install the supplied ca
INSTALLATION – CONTROLLERS 64 CONNECTING THE CONTROLLER(S) TO THE WATER HEATER To connect the controller(s) to the water heater: 1. Ensure the electr
65 COMMISSIONING All water heaters are tested and adjusted before dispatch from the factory, however further adjustments may become necessary becaus
COMMISSIONING 66 Gas Inlet Test Point Pressure To check the gas inlet pressure: 1. Close any hot taps and ensure the burners are not operating.
COMMISSIONING 67 BURNER GAS PRESSURE It is necessary to check the burner gas pressure at both the minimum and maximum operational settings. To check a
COMMISSIONING 68 Notes: If the burners extinguish and / or an error code starts to flash on the LED display: release the MIN and adjuster buttons
COMMISSIONING 69 PRESET OUTLET TEMPERATURE The factory preset outlet temperature of the water heater is: 871 series (pre 2007 manufacture date) 50°
ABOUT YOUR WATER HEATER 7 TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater: Turn off the controllers(s) (if fitted) by p
COMMISSIONING 70 TO CHECK OR ADJUST THE PRESET OUTLET TEMPERATURE The temperature settings will be displayed on the LED display. The preset temperatur
COMMISSIONING 71 TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater on completion of the installation, such as on a building
72 DRAINING THE WATER HEATER To drain the water heater: Turn off the water heater (refer to “Turn Off The Water Heater” on page 71). Open a hot
73 This page is intentionally blank.
74 This page is intentionally blank.
75 RHEEM ELECTRONIC CONTINUOUS FLOW GAS WATER HEATER WARRANTY – AUSTRALIA ONLY WARRANTY CONDITIONS 1. This warranty is applicable only to wa
RHEEM ELECTRONIC CONTINUOUS FLOW GAS WATER HEATER WARRANTY – AUSTRALIA ONLY Revision Date: 2008 October 31-76381-00 122133A 76 WARRANTY Rheem*
ABOUT YOUR WATER HEATER 8 HOW LONG WILL THE WATER HEATER LAST? There are a number of factors that will affect the length of service the
9 TEMPERATURE CONTROL CONTROLLERS The Rheem 871 and 875 series can be installed with Rheem controllers to enable the user to control the temperature