TEMPERATURE CONTROL DELUXE
38
Operation of the Bath Fill mode whilst a Deluxe Controller is ACTIVE
It is recommended the Bath Fill mode be set and operated with the Deluxe controllers turned off (refer to
Step 1 on page 32).
However, if a Deluxe controller is ACTIVE during the setting and operation of the Bath Fill mode, then the
following additional events occur:
During Step 3, when the bath fill temperature is being set
The temperature setting of the ACTIVE Deluxe controller will
display in the temperature display panel three seconds after
the BATH FILL TEMPERATURE button is last pressed.
When the Deluxe controller temperature setting is higher
than the bath fill temperature setting, the voice prompt will
sound;
“hot water temperature has been increased”
When the Deluxe controller temperature setting is lower than
the bath fill temperature setting, the voice prompt will sound;
“hot water temperature has been decreased”
During Step 6, when the BATH FILL button is pressed to turn the Bath Fill mode on
The Bath Fill mode has priority when operating. When the BATH FILL button is pressed, the Bath Fill mode
will gain priority and over-ride the settings of all Deluxe controllers if they are on.
The ACTIVE light will go out if it is on.
The bath fill temperature setting will replace the temperature
setting in the temperature display panel.
When the bath fill temperature setting is lower than the
Deluxe controller temperature setting, the voice prompt will
sound;
“hot water temperature has been decreased”
When the bath fill temperature setting is higher than the
Deluxe controller temperature setting, the voice prompt will
sound;
“hot water temperature has been increased”
During Step 9, when the BATH FILL button is pressed to turn the
Bath Fill mode off
The ACTIVE light will glow on the Deluxe controller which
has priority.
The temperature setting of the ACTIVE Deluxe controller will
display in the temperature display panel.
Notes
If it is a Bathroom Deluxe controller which is in use and it is on, i.e. it has priority and the ACTIVE light is
glowing, then it is advised to leave the controller on.
Refer to the warning in the notes on page 28.
If it is the Kitchen Deluxe controller which is in use and it is on, i.e. it has priority and the ACTIVE light is
glowing, then it is advised to turn the controller off.
Refer to Important note for Bathroom controllers on page 28.
“hot water temperature has
been increased”
or
“hot water temperature has
been decreased”
BATH (l)
46
°C
120
ACTIVE
ON/OFF
BATH FILL
“hot water temperature has
been decreased
or
“hot water temperature has
been increased
BATH (l)
40
°C
120
ACTIVE
BATH FILL
ON/OFF
BATH (l)
46
°C
120
ACTIVE
ON/OFF
BATH FILL
Seitenansicht 37