COMMISSIONING
67
BURNER GAS PRESSURE
It is necessary to check the burner gas pressure at both the minimum and maximum operational settings. To
check and if necessary adjust the operational gas pressures, the electrical supply to the water heater must
be switched on, the burners ignited and hot water must be flowing from a hot tap.
Warning: The removal of the front panel will expose 240 volt wiring. Take care not to touch wiring
terminals.
Minimum test point gas pressure
Refer to the rating label on the water heater for the minimum test point gas pressure.
1. Close any hot taps and ensure the burners are not operating.
2. Turn off the controller(s), if one is fitted, by pressing the
on / off button and switch off the electrical supply at the
power outlet to the water heater.
3. Remove the screws holding the front panel to the jacket.
4. Gently disengage the front panel and pull forward to
remove from the water heater.
5. Locate the burner pressure test point on the main burner
manifold.
Remove the test point screw and washer from the
test point orifice.
Connect the manometer.
6. Switch on the electrical supply at the power outlet to the
water heater and turn on a controller, if one is fitted, by
pressing the on / off button.
7. Open the gas isolation valve fully at the gas inlet to the water heater, if not already open.
8. Open a hot tap slowly until the burners ignite.
9. Press and hold down the MIN button and observe the
reading on the manometer.
“1L” is shown on the LED display.
10. Release the MIN button.
If the manometer reading observed in step 9 agrees with
the rating label, no further adjustment is required.
11. To adjust, press and hold down the adjuster button.
“LH” is shown on the LED display.
Note: The adjuster button must be held down
continuously through steps 11 to 13.
12. Press the MIN button and observe the reading on the
manometer.
Note: While the MIN button is pressed, the gas pressure will at first increase then decrease, cycling
between an upper gas pressure limit (39 on the LED display) and a lower gas pressure limit (01 on the
LED display).
13. Release the MIN button when the reading on the manometer agrees with the rating label.
14. Release the adjuster button.
manometer
test point
screw
test point
orifice
min button
max button
adjuster button
L.E.D.
display
washer