TEMPERATURE CONTROL DELUXE
36
Notes on the Bath Fill mode:
The Bath Fill mode can be set and turned on at any of the Deluxe controllers.
The Deluxe controllers do not require to have priority (ACTIVE light glowing) or be on in order to set the
bath fill water volume or bath fill temperature or to turn the BATH FILL button on.
The BATH FILL button cannot be turned on whilst a hot tap is open.
The bath fill water volume and the bath fill temperature settings can be adjusted whilst a hot tap is open.
If a hot tap is not opened for six hours after the new bath fill water volume and bath fill temperature has
been set, whilst the BATH FILL button is on, the settings will be automatically cancelled and will reset to
the previous settings or to the factory default settings if no previous settings have been set.
The factory default bath fill water volume setting is 180 litres.
The factory default bath fill temperature setting is 40°C.
The Bath Fill mode will automatically have priority when the BATH FILL button is pressed and the
Bath Fill mode is turned on. If the ACTIVE light is glowing on a Deluxe controller, it will go out. The
ACTIVE light on a Deluxe controller will not glow whenever the BATH Fill operating light is on.
Whilst water is flowing from a hot tap during the bath fill operation (BATH FILL operating light is on), a
Deluxe controller cannot be turned on or off:
if it is on, pressing the ON / OFF button will not turn it off
if it is off, pressing the ON / OFF button will not turn it on.
Whilst there is no water flowing from a hot tap and the BATH FILL operating light is on, a Deluxe
controller can be turned on (ON / OFF light glows), but it will not gain priority (ACTIVE light will not
glow).
Pressing the up () button or down () button above the ON / OFF button during the bath fill operation
(BATH FILL operating light is on) will not adjust the temperature setting.
Important
Ensure all hot taps are turned off after a bath fill operation is complete and before pressing the
BATH FILL button “OFF”. Otherwise;
Water will flow from the hot tap when the BATH FILL button is pressed “OFF.
The water will be cold if all Deluxe controllers are off, or hot if a Deluxe controller is ACTIVE.
The voice prompt will also sound;
please ensure the bath hot water tap is turned off”.